New Products for the PerkinElmer ® NexION 1000/2000 ICP-MS

Glass Expansion has 4 decades of experience manufacturing sample introduction components for ICP-MS and has earned a world-wide reputation for quality and reliability. Continuing this tradition, we are pleased to add the release of the D-Torch, the Helix Cyclonic Spray chamber and the Single Cell Sample introduction to the NexION 1000/2000 Product range.

A Robust, High Performance Demountable ICP Super Torch.

Figure 1. Exploded View of D-Torch

D-Torch

An Inductively Coupled Plasma (ICP) torch can be a costly consumable item requiring regular maintenance and replacement, particularly with aggressive sample matrices, such as hydrofluoric acid (HF), organic solvents and high total dissolved solids (TDS).

The patented D-Torch is a revolutionary demountable torch design from Glass Expansion. The D-Torch uses high precision engineering to provide the benefits of a fully demountable torch, such as lower running costs, chemical inertness and configurable injector geometry without compromising usability, performance or durability. Compared to other conventional torches, the D-Torch offers:

  • Better analytical precision with the unique tapered injector design
  • A choice of quartz, alumina and sapphire injectors in a range of diameters for aqueous, organic, high salt, fusions or HF containing samples
  • Lower running costs as only the outer tube is replaced when it wears
  • Easier cleaning and maintenance with the ability to remove the injector and outer tube and no O-rings to degrade and go brittle
  • The patented D-Torch is a revolutionary demountable super torch, which only requires you to replace the components that are warn.

Ordering Information

Part Number Description
30-808-3927 D-Torch for PE NexION 1000/2000 (without Injector)
31-808-3928 Base and Inner Tube for D-Torch
31-808-3942 Quartz Outer Tube for D-Torch
31-808-2818 Retaining Ring for D-Torch
Torch Injector Options  
31-808-3302 Tapered Quartz Injector 2.5mm
31-808-4006 Tapered Quartz Injector 2.0mm
31-808-4005 Tapered Quartz Injector 1.8mm
31-808-4004 Tapered Quartz Injector 1.5mm
31-808-3423 Tapered Quartz Injector 1.0mm
31-808-3205 Tapered Alumina Injector 2.4mm
31-808-3378 Sapphire Injector 2.4mm


Helix CT (ConstantTorque) Spray Chamber

Figure 2. Helix CT (ConstantTorque) Spray Chamber

Spray Chamber

The spray chamber is a crucial component of the ICP sample introduction system since it has a profound effect on transport efficiency, precision, and washout. Glass Expansion revolutionized spray chamber design with the Tracey and Twister single-pass and double-pass cyclonic spray chambers, providing improved transport efficiency and reduced washout. Glass Expansion's unique Helix CT nebulizer interface features an inert PTFE seal to eliminate dead-volume giving quicker washout and higher sample throughput.

The Glass Expansion cyclonic spray chambers for the NexION ICP-MS have a:

  • Double-pass Twister™ version with central baffle that rejects large droplets from the nebulizer aerosol for best short-term precision and lowest interferences
  • Single-pass Tracey™ version for the highest sensitivity
  • Vertical wall design that improves transport efficiency and short-term precision by ensuring smooth drainage of excess sample
  • Positive stop on the Helix CT nebulizer interface ensures consistent nebulizer positioning in the spray chamber for reproducible long-term analytical performance
  • Side-wall groove that improves drainage and prevents sample re-nebulization
  • Inert PTFE seal (no oring's) that cannot stick to the nebulizer and is easier to clean
  • Low volume (20mL) options available for high sample throughput

Ordering Information

Part Number Description
20-809-4417HE Twister Spray Chamber with Helix CT
20-809-4419HE Tracey Spray Chamber with Helix CT
20-809-4482HE Twinnabar Spray Chamber with Helix CT
20-809-4480HE Cinnabar Spray Chamber with Helix CT


High Efficiency Sample Introduction System (HE-SIS)

Figure 3. HE-SIS Diagram

Single-cell analysis by ICP-MS (SC-ICP-MS) is enhancing the basic understandings in cellular biology, oncology and drug discovery. SC-ICP-MS allows quantification of metals in individual biological cells at ultra-low detection levels not previously seen in other techniques. SC-ICP-MS can be used to study disease aetiology, provide a better understanding of diseased cell states and develop new drug treatments for better patient outcomes.

The Glass Expansion High Efficiency Sample Introduction System features:

  • An on-axis, high efficiency laminar flow spray chamber
  • A MicroJet Make-up gas adapter that provides high velocity sheathing gas that entrains and shapes the nebulizer aerosol plume to prevent cell deposition on the spray chamber walls
  • High efficiency, low uptake, concentric glass nebulizer designed to efficiently nebulize single-cell suspensions without compromising cell integrity

Ordering Information

Part Number Description
KT-1184 HE-SIS for PerkinElmer® NexION 1000/2000/5000 ICP-MS